"When Knowledge and Experience Matters"
Dryer Vent Safety
Dryer Vent Safety

- It should be connected. The connection is usually behind the dryer but may be beneath it. Look carefully to make sure it’s actually connected!
- It should not be restricted. Dryer vents are often made from flexible plastic or metal duct, which may be easily kinked or crushed where they exit the dryer and enter the wall or floor. This is often a problem since dryers tend to be tucked away into small areas with little room to work. Vent hardware is available which is designed to turn 90° in a limited space without restricting the flow of exhaust air. Restrictions should be noted in the inspector's report. Airflow restrictions are a potential fire hazard!
- One of the reasons that restrictions are a potential fire hazard is that, along with water vapor evaporated out of wet clothes, the exhaust stream carries lint – highly flammable particles of clothing made of cotton and polyester. Lint can accumulate in an exhaust duct, reducing the dryer’s ability to expel heated water vapor, which then accumulates as heat energy within the machine. As the dryer overheats, mechanical failures can trigger sparks, which can cause lint trapped in the dryer vent to burst into flames. This condition can cause the whole house to burst into flames! Fires generally originate within the dryer but spread by escaping through the ventilation duct, incinerating trapped lint, and following its path into the building wall.
The recommendations outlined below reflect International Residential Code (IRC) SECTION M1502 CLOTHES DRYER EXHAUST guidelines:
M1502.5 Duct construction.
Exhaust ducts shall be constructed of minimum 0.016-inch-thick (0.4 mm) rigid metal ducts, having smooth interior surfaces, with joints running in the direction of air flow. Exhaust ducts shall not be connected with sheet-metal screws or fastening means which extend into the duct.
M1502.6 Duct length.The maximum length of a clothes dryer exhaust duct shall not exceed 25 feet (7,620 mm) from the dryer location to the wall or roof termination. The maximum length of the duct shall be reduced 2.5 feet (762 mm) for each 45-degree (0.8 rad) bend, and 5 feet (1,524 mm) for each 90-degree (1.6 rad) bend. The maximum length of the exhaust duct does not include the transition duct.
A couple of exceptions exist:
- The IRC will defer to the manufacturer’s instruction, so if the manufacturer’s recommendation permits a longer exhaust vent, that’s acceptable. An inspector probably won’t have the manufacturer’s recommendations, and even if they do, confirming compliance with them exceeds the scope of a General Home Inspection.
- The IRC will allow large radius bends to be installed to reduce restrictions at turns, but confirming compliance requires performing engineering calculation in accordance with the ASHRAE Fundamentals Handbook, which definitely lies beyond the scope of a General Home Inspection!
M1502.2 Duct termination.
Exhaust ducts shall terminate on the outside of the building or shall be in accordance with the dryer manufacturer’s installation instructions. Exhaust ducts shall terminate not less than 3 feet (914 mm) in any direction from openings into buildings. Exhaust duct terminations shall be equipped with a backdraft damper. Screens shall not be installed at the duct termination.
M1502.3 Duct size.
The diameter of the exhaust duct shall be as required by the clothes dryer’s listing and the manufacturer’s installation instructions.
M1502.4 Transition ducts.
Transition ducts shall not be concealed within construction. Flexible transition ducts used to connect the dryer to the exhaust duct system shall be limited to single lengths not to exceed 8 feet (2438 mm), and shall be listed and labeled in accordance with UL 2158A.

Certified Georgia Home Inspector Serving..
Butts County - Flowilla, Jackson. Clayton County - Ellenwood, Forest Park, Jonesboro, Lake City, Lovejoy, Morrow, Rex, Riverdale. Cobb County - Austell, Mableton, Marietta, Powder Springs. Coweta County - Grantville, Haralson, Moreland, Newnan, Senoia, Sharpsburg, Turin. Dekalb County - Avondale Estates, Chamblle, Clarkston, Decatur, Lilburn, Lithonia, Scottdale, Stone Mountain, Tucker. Douglas County - Douglasville, Lithia Springs, Winston. Fayette County -Brooks, Fayetteville, Peachtree City, Tyrone, Woolsey. Fulton County - Alpharetta, Atlanta, Collage Park, East Point, Fairburn, Johns Creek, Roswell, Sandy Springs, Union City. Henry County - Hampton, Locust Grove, McDonough, Stockbridge. Lamar County - Barnesville, Milner. Meriwether County - Greenville, Luthersville, Warm Springs, Woodbury. Monroe County - Culloden, Forsyth. Newton County - Covington, Porterdale. Pike County - Concord, Meansville, Molena, Williamson, Zebulon. Rockdale County - Conyers. Spalding County - Griffin, Orchard Hill, Sunny Side. Upson County - The Rock, Thomaston, Yatesville.